2012 IRC Egress Codes - Quick Glance

Window Well Requirements for Egress

Minimum
Width

36"

Minimum
Projection

36"

Maximum
Depth

44"

Without an Egress Ladder

Maximum
Depth


With a Permanent Egress Ladder

Basement Window Requirements for Egress

Minimum
Opening

5.7 ft²

Above Grade

Minimum
Opening

5 ft²

Below Grade

Minimum
Width

20"

Minimum
Height

24"


Last updated: Saturday, July 1, 2017
Notice: Please verify with your local county building inspector to double check your code requirements before starting a project. We try to keep this database up-to-date as best as possible, but express no warranties on accuracy of information. If you find a mistake or have any questions, please Contact Us or call 1-888-650-9355

2012 International Residential Code

SECTION R310 – EMERGENCY ESCAPE AND RESCUE OPENINGS

R310.1 Emergency escape and rescue required.

Basements. habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) measured from the finished floor to the bottom of the clear opening. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section R310.3. The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with Section R310.2. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way. Exception: Basements used only to house mechanical equipment and not exceeding total floor area of 200 square feet (18.58 m2).
R310.1.1 Minimum opening area.
All emergency escape and rescue openings shall have a minimum net clear open ing of 5.7 square feet (0.530 m2). Exception: Grade floor openings shall have a mini mum net clear opening of 5 square feet (0.465 m2).
R310.1.2 Minimum opening height.
The minimum net clear opening height shall be 24 inches (610 mm).
R310.1.3 Minimum opening width.
The minimum net clear opening width shall be 20 inches (508 mm).
R310.1.4 Operational constraints.
Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys, tools or special knowledge.

R310.2 Window wells.

The minimum horizontal area of the window well shall be 9 square feet (0.9 m2), with a minimum horizontal projection and width of 36 inches (914 mm). The area of the window well shall allow the emergency escape and rescue opening to be fully opened. Exception: The ladder or steps required by Section R310.2.1 shall be permitted to encroach a maximum of 6 inches (152 mm) into the required dimensions of the window well.
R310.2.1 Ladder and steps.
Window wells with a vertical depth greater than 44 inches (1118 mm) shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or steps required by this section shall not be required to comply with Sections R311.7 and R311.8. Ladders or rungs shall have an inside width of at least 12 inches (305 mm), shall project at least 3 inches (76 mm) from the wall and shall be spaced not more than 18 inches (457 mm) on center vertically for the full height of the window well.
R310.2.2 Drainage.
Window wells shall be designed for proper drainage by connecting to the building’s foundation drainage system required by Section R405.1 or by an approved alternative method. Exception: A drainage system for window wells is not required when the foundation is on well-drained soil or sand-gravel mixture soils according to the United Soil Classification System, Group ISoils, as detailed in Table R405.1.

R310.3 Bulkhead enclosures.

Bulkhead enclosures shall provide direct access to the basement. The bulkhead enclosure with the door panels in the fully open position shall provide the minimum net clear opening required by Section R310.1.1. Bulkhead enclosures shall also comply with Section R311.7.8.2,

R310.4 Bars, grilles, covers and screens.

Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided the mini mum net clear opening size complies with Sections R310.1.1 to R310.1.3, and such devices shall be releasable or removable from the inside without the use of a key, tool, special knowledge or force greater than that which is required for normal operation of the escape and rescue opening.

R310.5 Emergency escape windows under decks and porches.

Emergency escape windows are allowed to be installed under decks and porches provided the location of the deck allows the emergency escape window to be fully opened and provides a path not less than 36 inches (914 mm) in height to a yard or court.

Browse By Cities / Counties in Texas

If your city or county is not listed here, please contact your local county building inspector for more information.
Ames
Andrews
Angleton
Anna
Argyle
Arlington
Athens
Austin
Balch Springs
Bandera
Baytown
Bayview
Beaumont
Bedford
Bee Cave
Bellaire
Bells
Benbrook
Bevil Oaks
Bexar County
Big Spring
Boerne
Bonham
Bowie
Boyd
Brady
Brazoria
Breckenridge
Brenham
Bridge City
Bridgeport
Brownsville
Brownwood
Bryan
Bulverde
Burkburnett
Burleson
Burnet
Cameron
Canton
Canyon
Carrollton
Castle Hills
Castroville
Cedar Hill
Cedar Park
Celina
Chandler
Cibolo
City of the Colony
Clear Lake Shores
Cleburne
Cleveland
College Station
Colleyville
Conrinth
Conroe
Converse
Coppell
Copper Canyon
Copperas Cove
Corinth
Corpus Christi
Crowley
Cumby
Dallas
Del Rio
Denton
DeSoto
Dilley
Duncanville
Eagle Pass
El Paso
Electra
Elgin
Ennis
Euless
Everman
Farmers Branch
Flatonia
Flower Mound
Fort Stockton
Fort Worth
Fredericksburg
Friendswood
Frisco
Gainesville
Galveston
Garden Ridge
Garland
Gatesville
Georgetown
Giddings
Gilmer
Gladewater
Glen Rose
Glenn Heights
Goliad
Gonzales
Graham
Granbury
Grand Prairie
Grapevine
Greenville
Groves
Gun Barrel City
Hallettsville
Haltom City
Hamilton
Harker Heights
Harlingen
Harris County
Hedwig Village
Helotes
Hereford
Hidalgo
Highland Park
Highland Village
Hillsboro
Houston
Hubbard
Humble
Huntsville
Hurst
Hutchins
Hutto
Irving
Italy
Jersey Village
Jonestown
Katy
Kaufman County
Keene
Keller
Kemah
Kennedale
Kerrville
Kilgore
Killeen
Kingsville
Lago Vista
LaGrange
Lake Dallas
Lake Jackson
Lake Worth
Lakeway
LaMarque
Lancaster
LaPorte
Laredo
League City
Leander
Leon Valley
Levelland
Lewisville
Lexington
Liberty Hill
Lindale
Little Elm
Live Oak
Llano
Lockhart
Longview
Lorena
Lubbock
Lufkin
Magnolia
Mansfield
Manvel
Marble Falls
Marshall
Mason
McAllen
McGregor
McKinney
Meadowlakes
Melissa
Mercedes
Mesquite
Mexia
Midland
Midlothian
Milford
Mineola
Mission
Missouri City
Monahans
Mont Belvieu
Montgomery
Morgan’s Point Resort
Mount Pleasant
Nacogdoches
Nassau Bay
Nederland
New Braunfels
Newark
Nolanville
North Richland Hills
Oak Leaf
Odessa
Onalaska
Orange
Palestine
Pantego
Parker
Pearland
Pflugerville
Pharr
Pilot Point
Plano
Pleasanton
Port Aransas
Port Arthur
Port Isabel
Port Neches
Portland
Presidio
Prosper
Red Oak
Richardson
Richmond
Rio Grande City
Rockport
Rockwall
Roma
Rosenberg
Round Rock
Rowlett
Runaway Bay
Sachse
Sadler
Saginaw
Salado
San Angelo
San Antonio
San Benito
San Diego
San Juan
San Marcos
San Saba
Santa Fe
Schertz
Seagoville
Sealy
Seguin
Selma
Shavano Park
Shenandoah
Sherman
Silsbee
Sinton
Sonora
South Houston
South Padre Island
Southlake
Spring Valley
Springtown
Stafford
Stanton
Stephenville
Stockdale
Sugar Land
Taft
Terrell
Texas City
The Colony
Thorndale
Tom Bean
Travis County
Tyler
Universal City
University Park
Uvalde
Venus
Vernon
Victoria
Vidor
Volente
Waco
Waller
Watauga
Waxahachie
Weatherford
Webster
West Orange
Westlake
Westworth Village
Wharton
Whimberley
White Oak
Wichita Falls
Willis
Winnsboro
Wylie

United States IRC Code Adoption PDF - by state

Find Your State's IRC Code Adoption

Download the State Local Codes Chart PDF to determine which International Residential Code your state follows. Depending on your State, your local county may have additional/different requirements. Please refer to your local government website for up-to-date information and to confirm the information on this page.